Heavy-duty steel grating price depends on the load it must carry, the unsupported span, the bearing bar dimensions, and the supporting structure. A higher load requirement usually increases material weight, fabrication work, or support costs, but there is no universal price attached to a label such as “heavy duty” or “vehicle rated.” For early planning, CSSP’s published guide lists approximately US$90–300 per square meter for heavy-duty galvanized steel grating. This is a broad factory-budget reference, not a quotation for a certified load class. Accurate pricing requires the actual load, contact area, span, support details, material, finish, and acceptance requirements.
Load requirements determine whether a grating panel can safely support its intended use. They also influence steel consumption, manufacturing, frame design, installation, and long-term maintenance. A pedestrian walkway and a forklift crossing can cover the same area while requiring very different products.
Purchasers often begin with a label such as light duty, medium duty, heavy duty, or extra heavy duty. These descriptions are useful for an initial discussion, but their meanings vary between suppliers. They do not replace a design load, a recognized classification system, or a verified load table.
The first pricing task is therefore to establish what “load class” means for the project. It may describe an informal application category, an engineer-specified design load, or a formal classification under a particular product standard. Each requires different evidence.

A higher-rated panel does not always cost more than every lower-rated panel. A short-span vehicle cover may use less steel than a much wider platform panel carrying a lower distributed load. Stainless material, custom openings, removable access details, and special finishing can also outweigh the effect of nominal load category.
Compare prices only after the technical basis is consistent. Otherwise, a cheaper offer may simply use a shorter assumed span, a larger load footprint, a more permissive deflection limit, or an incomplete support arrangement.
Heavy-duty steel grating is bar grating designed for demanding loads such as industrial equipment, concentrated wheel loads, repeated traffic, and impact. It generally uses deeper or thicker bearing bars than standard pedestrian grating, together with suitable cross members, edge details, supports, and restraints.
The bearing bars carry the main bending load between supports. Cross bars connect and stabilize them and may contribute to load distribution according to the product construction. Their presence does not make every panel equally strong in both directions.
A thick-looking panel is not automatically suitable for heavy traffic. Capacity depends on its clear span, bearing bar orientation, material properties, connections, support bearing, and the position and footprint of the load.
Similarly, a panel that performs adequately under a stationary load may need additional assessment for repeated forklift crossings, braking, turning, vibration, or impact.
Each application needs a defined load case. The phrase “suitable for industrial use” is not enough to establish a heavy-duty rating.
Steel grating does not have one universal load-class system covering every walkway, platform, trench cover, and road installation. The applicable design method depends on the product, country, installation, and contract requirements.
Light duty, medium duty, and heavy duty are often commercial descriptions. One manufacturer may use “heavy duty” for a reinforced pedestrian panel, while another reserves it for thick-bar vehicular grating.
These descriptions should be supported by numerical loading requirements and a stated span before they are used for purchasing.
Industrial grating is frequently selected using uniformly distributed loads, concentrated loads, line loads, wheel loads, and allowable deflection. The engineer also defines the applicable load combinations, design method, and any dynamic or fatigue requirements.
A panel may have several different capacities depending on the load case. Its uniform-load rating does not automatically establish its wheel-load rating.
Some drainage and access products use classifications such as A15, B125, C250, D400, E600, and F900 within standards including EN 124 or EN 1433, where their respective scopes apply. These standards address different product systems and installation conditions. A classification under one should not be treated as automatic compliance with another.
The following table is an orientation guide to familiar class labels. It does not assign a class to ordinary bar grating or replace the applicable standard’s location rules, construction requirements, and tests.
| Class Label | Associated Test-Load Value | General Installation Context | Purchasing Check |
|---|---|---|---|
| A15 | 15 kN | Areas restricted to pedestrians and cyclists, where permitted by the applicable standard | Confirm that vehicle access is excluded and the product standard applies |
| B125 | 125 kN | Selected pedestrian, parking, and comparable locations within the standard’s scope | Verify the exact installation category and traffic exposure |
| C250 | 250 kN | Specified kerbside or drainage locations, depending on the product standard | Use the standard’s location rules rather than a general vehicle-weight assumption |
| D400 | 400 kN | Carriageways and other applicable road-traffic areas | Verify the complete product or assembly and its installation requirements |
| E600 | 600 kN | Areas imposing high wheel loads, subject to the applicable standard | Confirm product qualification and actual operational loading |
| F900 | 900 kN | Areas imposing particularly high wheel loads | Require the specified qualification and project-specific installation design |
These numbers are associated test loads under defined conditions. They are not allowable vehicle masses. A D400 label does not mean that any 40-tonne vehicle can cross any grating panel, at any span, with any supporting frame.
A quotation for an engineered industrial panel and a quotation for a formally classified cover assembly may include different testing, frame details, documentation, and manufacturing controls. Those differences must be visible in the price comparison.
If formal classification is required, identify the standard, edition, product scope, dimensions covered by the evidence, and installation arrangement. Do not accept an unrelated test certificate as proof that every panel in the order has the same classification.
Higher loads can require larger bearing bars, additional supports, reinforced panel edges, or a different construction. Concentrated loads and repeated traffic can add requirements that are absent from ordinary pedestrian designs.
Acceptance testing and engineering documentation also cost money. Where required, include calculations, load testing, inspection attendance, traceability, and dimensional verification in the request for quotation.
Bearing bar dimensions usually have the largest influence on grating weight. Increasing thickness adds metal directly. Increasing depth adds metal while also improving bending stiffness.
Closer spacing increases the number of bearing bars per square meter. It can also change how a wheel footprint engages the panel, but load sharing should be established by the product’s design method rather than assumed.
Closer cross bars add material and intersections. Their influence on capacity depends on whether the product is welded, press-locked, swage-locked, or riveted.
A denser cross-bar pattern does not automatically compensate for undersized bearing bars. Compare the verified performance of the complete panel.
The overall panel length is not necessarily the unsupported span. A long panel can have intermediate supports, while a short cover may span nearly its entire length.
Additional supports can reduce the required grating section, but they create costs for beams, frames, connections, coatings, and installation. The least expensive panel is not always the least expensive platform system.
Carbon steel, galvanized carbon steel, and stainless steel have different purchase and maintenance costs. Higher-strength steel may improve a strength check, but it does not materially increase elastic stiffness in the way that a deeper bar does.
Where deflection governs the design, changing to a higher-strength grade alone may provide little benefit.
Cutouts, load-bearing banding, shaped edges, lifting points, toe plates, hinges, and access openings add work. An opening that interrupts bearing bars can also require structural reinforcement or a dedicated support.
Repeated panels allow production efficiencies. Small custom batches may carry minimum material, setup, galvanizing, or inspection charges.
Heavy panels also affect packing, freight, crane selection, support handling, and installation productivity. Include those consequences when evaluating a heavier section.
The categories below describe practical operating conditions. They are not formal load classes and do not replace numerical design requirements.
| Duty Category | Typical Applications | Key Design Inputs | Likely Cost Drivers |
|---|---|---|---|
| Light-duty pedestrian access | Inspection paths and restricted access areas | Required pedestrian loads, span, deflection, and openings | Basic section size, surface profile, and finish |
| Medium-duty walkways and platforms | Regular industrial access and maintenance platforms | Personnel, tools, maintenance loads, and vibration | Stiffer bars, banding, cutouts, and restraints |
| Heavy industrial duty | Processing areas, loaded carts, and concentrated equipment access | Actual contact loads, repeated loading, and local support conditions | Large bars, reinforcement, support steel, and fabrication |
| Vehicle and forklift duty | Trench crossings, warehouse routes, and service yards | Wheel loads, tire footprints, travel direction, dynamic effects, and traffic frequency | Heavy sections, robust frames, edge support, and secure fastening |
| Special equipment duty | Machinery access, temporary maintenance loading, and unusual plant operations | Equipment feet, outriggers, transport wheels, and operating load combinations | Project-specific engineering and dedicated support details |
A walkway may need to support maintenance tools, temporary materials, or emergency access loads. Do not reduce the design to the expected weight of one person.
A forklift rated to lift a particular mass does not apply that mass evenly to the floor. The truck’s own weight, payload, load position, axle distribution, tire type, and operating condition determine wheel loading.
Obtain the maximum relevant axle and wheel reactions from the equipment information. Include braking, turning, and impact effects as required by the project design.
A machinery foot, jack, or outrigger may impose a high force over a small area. Ordinary vehicle-grating data may not cover it. Dedicated load-spreading or support arrangements may be needed.
A stronger design may use deeper bars, thicker bars, closer spacing, shorter spans, or a combination. Each approach changes both panel cost and the surrounding structure.
The best solution depends on access, available depth, fabrication, and installation. A deeper panel may be economical when new support beams would be difficult to install.
For a simplified simply supported beam under a uniformly distributed line load, bending moment increases with the square of span and deflection with the fourth power of span. Real grating selection must account for its construction and loading, but this relationship explains why modest span changes can significantly affect the required section.
Doubling the span while keeping the same bar and distributed line load would increase the simple-beam deflection by a factor of sixteen. This is not a load rating for a grating panel; it illustrates why span information is essential to pricing.
A wide contact area may engage several bearing bars. A narrow hard wheel can concentrate load on fewer bars. The direction of travel relative to the bars and the position near an edge or joint can change the critical condition.
A wheel-load quote should identify the assumed contact footprint. Using an oversized footprint can make a panel appear more capable than it is under the actual equipment.
Repeated traffic introduces considerations such as connection durability, fatigue, panel movement, wear, and loss of restraint. A single static proof test does not by itself demonstrate unlimited fatigue life.
The load travels from the grating through its bearing surfaces into the frame and supporting structure. Inadequate frame stiffness, insufficient bearing, weak anchors, or a damaged concrete edge can govern system performance even when the grating bars are adequate.
Price the complete required load path rather than upgrading the panel alone.
A load table is useful only when its assumptions match the project. Read the notes, units, and limitations before selecting a row.
Confirm the material, bearing bar depth and thickness, spacing, cross-bar arrangement, manufacturing method, and surface profile. A table for plain welded carbon steel grating may not apply to serrated stainless steel or another construction.
Check whether the table uses clear span or another stated support dimension. Match it to the actual drawing. Do not substitute overall panel length unless the table defines that as the relevant dimension.
Tables may list uniform load, concentrated load, line load, or wheel load. These quantities are different and cannot be exchanged without calculation.
| Table Item | Possible Unit | Meaning | Common Misreading |
|---|---|---|---|
| Uniformly distributed load | kN/m² or psf | Load distributed over an area under the table’s assumptions | Treating it as the rating for a concentrated wheel |
| Line load | kN/m or lb/ft | Load distributed along a stated line | Reading it as total load over the whole panel |
| Concentrated load | kN or lb | Force applied over a stated footprint or arrangement | Ignoring the contact area and load position |
| Deflection | mm or inches | Calculated movement under a stated load | Assuming it applies at every listed capacity |
| Span | mm, m, or inches | The support dimension defined by the table | Using overall panel length without checking the definition |
An allowable load, a factored design resistance, an ultimate test result, and a proof load are different quantities. Read the design basis before comparing the table with project loading.
Do not apply an arbitrary safety factor to a table that already includes one, or treat an ultimate test result as a working capacity. The engineer should reconcile the table’s method with the project’s design method.
A product may have adequate strength but exceed the required deflection limit. Check both criteria and confirm whether the table includes an absolute deflection limit, a span-based limit, or another serviceability requirement.
Check the required bearing length, support condition, edge details, and whether cutouts or field modifications are permitted. A table for an intact rectangular panel may not apply after bearing bars have been cut around a pipe.
Assume a project requires a panel over a 900 mm clear span to carry a 7.5 kN/m² service uniform load, with deflection limited to 4 mm. A hypothetical table gives Candidate A an allowable uniform load of 10 kN/m² at that span and states a deflection of 3 mm under 7.5 kN/m².
Candidate A would satisfy those two stated uniform-load criteria if all other assumptions match. It would still need any required concentrated-load, wheel-load, edge, connection, and support checks. This example demonstrates table reading only; it does not specify an actual grating section.
1 kN/m² = 1 kPa
1 kN ≈ 224.81 lbf
1 kN/m² ≈ 20.89 psf
Mass in kilograms is not force. Avoid converting a vehicle’s total mass directly into an allowable grating load without considering gravity, axle distribution, wheel footprints, and the applicable design conditions.
Welded grating is widely used for industrial platforms and heavy-duty covers. Standard production arrangements can provide economical manufacturing, while deep or thick sections may require specialized equipment or fabrication procedures.
Price depends on bar weight, mesh, welding, banding, cutting, and finishing. The quotation should identify the load table or calculation that supports the proposed section.
Press-locked grating uses bars assembled through prepared slots or notches. Cost depends on slot preparation, bar arrangement, pressing, mesh, and edge finishing.
Availability of heavy-duty configurations varies. Do not assume that a neat or symmetrical grid has the same capacity in both directions; confirm which members are load-bearing and how the product is rated.
Swage-locked systems mechanically secure cross members to bearing bars. Material options, cross-member profiles, locking details, and heavy-duty availability depend on the manufacturer.
Compare only products with documented performance for the required traffic and span. A mechanically locked standard walkway product should not be treated as a heavy-duty alternative without supporting data.

Riveted grating uses mechanically fastened members in a product-specific arrangement. It is used in selected demanding applications, including some traffic and infrastructure installations.
Riveting, component preparation, assembly, and limited supplier availability can affect cost. Potential benefits under particular loading conditions should be demonstrated by the product’s design and service evidence rather than assumed from the fastening method alone.
| Construction | Main Price Drivers | Important Heavy-Duty Check |
|---|---|---|
| Welded | Bar weight, welding capability, repeated quantities, and finish | Welded-panel capacity, connections, edge details, and wheel-load assumptions |
| Press-locked | Slotting, bar configuration, pressing, and fabrication | Bearing direction, section properties, and rated load conditions |
| Swage-locked | Profiles, preparation, locking process, and availability | Suitability of the specific product for the required duty |
| Riveted | Components, mechanical assembly, supplier availability, and custom work | Documented static, repeated-load, and connection performance where required |
CSSP’s steel grating prices, sizes, and load capacity guide publishes broad factory-budget ranges for several product categories. These can support early estimating, but they do not establish prices for specific formal load classes.
| Product Category | Published Factory-Budget Reference | How to Use It |
|---|---|---|
| Standard hot-dip galvanized grating | Approximately US$25–80/m² | Initial allowance for conventional panels; verify the actual load and span |
| Fabricated galvanized grating | Approximately US$40–140/m² | Planning reference for panels with specified fabrication; confirm included work |
| Heavy-duty galvanized grating | Approximately US$90–300/m² | Broad allowance for larger sections and demanding loads; obtain a design-based quote |
The ranges overlap because weight, fabrication, quantity, and finish differ. They exclude a universal allowance for frames, formal class qualification, freight, installation, duties, or taxes.
There is no supported conversion such as “D400 costs a fixed amount more than C250.” A formal class requirement must be priced using the actual dimensions, complete assembly, manufacturing requirements, and evidence of compliance.
Confirm loads, span, deflection, material, surface profile, support conditions, and any formal classification. Pricing a section before establishing its suitability can create misleading savings.
Panel area in m² = length in meters × width in meters
Separate purchased area from installed area. Cutting layouts, spare panels, and minimum production sizes can make the purchased quantity larger than the finished coverage.
For rectangular carbon steel bearing bars, a preliminary continuous-grid estimate is:
Bearing-bar-only weight in kg/m² ≈ 7.85 × height in mm × thickness in mm ÷ center spacing in mm
For example, 50 × 6 mm bars at 30 mm centers contribute approximately 78.5 kg/m² before cross bars, banding, attachments, and coating.
This weight estimate does not establish a load rating. Finished panel weight should come from the approved design or supplier calculation.
Supply price per m² = finished-grating price per metric tonne × matching finished weight in kg/m² ÷ 1,000
At an illustrative finished-grating rate of US$1,500 per metric tonne and a matching unit weight of 90 kg/m²:
US$1,500 × 90 ÷ 1,000 = US$135/m²
The rate must refer to finished grating with an identified scope. A raw steel rate cannot be used as the complete manufactured panel price.
Include frames, support modifications, anchors, restraints, testing, packing, freight, unloading, labor, lifting, and required site controls. Avoid adding items twice when they are already included in a supplier package.
The following example demonstrates budgeting rather than market pricing. Assume 40 m² of installed grating and 42 m² purchased, representing a 5% overage relative to installed area. The hypothetical base rate is US$150/m² for panels already verified against the project loads.
| Budget Item | Calculation or Allowance | Illustrative Cost |
|---|---|---|
| Heavy-duty galvanized panels | 42 m² × US$150/m² | US$6,300 |
| Additional cutouts and reinforced edges | Work beyond base panel scope | US$900 |
| Frames and support modifications | Project-specific allowance | US$2,200 |
| Restraints and fastening assemblies | Approved layout allowance | US$400 |
| Packing and freight | Illustrative shipment allowance | US$850 |
| Installation and lifting | Illustrative site allowance | US$1,800 |
| Engineering and inspection documentation | Illustrative scope allowance | US$600 |
| Subtotal | Sum of listed items | US$13,050 |
| Planning contingency | 10% for this example | US$1,305 |
| Total example budget | Subtotal plus contingency | US$14,355 |
| Budget per installed square meter | US$14,355 ÷ 40 m² | Approximately US$358.88/m² |
The example excludes taxes, import duties, major civil works, and any special full-scale qualification testing. Its allowances are not a quote for a formal load class. Add known requirements directly and select contingency according to the remaining uncertainty.
| Required Information | What to State | Why It Matters |
|---|---|---|
| Application | Walkway, platform, trench crossing, vehicle route, or equipment area | Identifies relevant operating conditions |
| Classification basis | Formal standard and class, or numerical engineering loads | Prevents ambiguous duty descriptions |
| Span and supports | Clear opening, bearing arrangement, intermediate supports, and frame drawing | Defines the structural load path |
| Uniform and concentrated loads | Magnitude, footprint, location, and combinations | Allows the correct load cases to be checked |
| Vehicle data | Maximum relevant wheel or axle reactions, tire type, footprint, and travel direction | Defines local panel loading |
| Operating conditions | Traffic frequency, speed, turning, braking, impact, and vibration where relevant | Identifies dynamic and repeated-load requirements |
| Serviceability | Allowable deflection and movement criteria | Controls stiffness and operational performance |
| Material and finish | Steel grade, galvanizing, coating, or stainless treatment | Defines material and durability costs |
| Panel schedule | Dimensions, quantity, orientation, cutouts, banding, and panel marks | Supports accurate fabrication pricing |
| Accessories | Clips, bolts, hinges, locks, handles, frames, and anchors | Clarifies whether a complete assembly is required |
| Verification | Calculations, tests, material reports, inspection, and acceptance criteria | Defines the evidence required for approval |
| Delivery | Destination, commercial terms, required date, and unloading conditions | Creates a comparable delivered-cost basis |
Please quote heavy-duty galvanized steel grating for the attached trench layout and equipment loading schedule. Verify the panels, edge details, frames, and restraints against the stated wheel loads, contact footprints, clear spans, and deflection limits. Identify the proposed construction, material, unit weight, finish, and verification documents. Itemize fabrication, frames, fixings, packing, delivery, and any testing exclusions.
If a formal product class is required, add the exact standard, edition, class, and required evidence. Attach the real loading and geometry; the wording alone is not a technical specification.
Base the design on documented equipment and traffic information. Avoid selecting an unnecessarily large panel because the vehicle information is incomplete, but do not reduce demand based on informal estimates.
A platform may have pedestrian areas, maintenance routes, and isolated equipment positions. Separate engineered zones can prevent the heaviest section from being used everywhere.
Different ratings should be clearly identified and controlled so that heavy equipment is not later routed over a lighter zone.
An intermediate support can reduce panel demand, but its cost, access implications, and effect on drainage or equipment clearance must be included. In some projects, a deeper panel is more economical than installing additional steelwork.
If heavier equipment is planned, include it in the design brief. An intentional future-load allowance is different from adding an unexplained “extra heavy” margin to every panel.
Cost optimization should come from geometry, layout, material efficiency, and fabrication planning. It should not remove code-required factors, testing, bearing, restraints, or serviceability criteria.
| Comparison | Standard Industrial Grating | Heavy-Duty Grating |
|---|---|---|
| Typical duty | Pedestrian and general maintenance access | Higher concentrated loads, equipment, and verified traffic service |
| Bearing bars | Sections selected for ordinary access requirements | Often deeper, thicker, or more closely spaced |
| Weight | Generally lower for comparable panel geometry | Generally higher, affecting transport and handling |
| Edge and frame details | Conventional banding and support arrangements | May require reinforced edges and stronger support assemblies |
| Installation | May allow lighter handling equipment | Often needs mechanical lifting and more substantial restraints |
| Verification | Applicable load-table checks and project inspection | More detailed wheel-load, repeated-load, or assembly verification where required |
| Initial cost | Usually lower | Usually higher because of material and system requirements |
Heavy-duty grating is not automatically the best choice for every area. Unnecessary weight can increase frame loads, lifting costs, and maintenance difficulty. Conversely, standard grating should not be used in a traffic zone merely because it fits the opening.
Galvanizing is widely used for carbon steel industrial grating. Costs depend on panel weight, batch charges, dimensions, steel chemistry, handling, and finishing work.
Complete cutting, banding, and welding before galvanizing where the fabrication sequence permits. Specify coating requirements, inspection, dimensional acceptance, and repair procedures for damaged areas.
Galvanizing provides corrosion protection; it should not be credited as structural bearing-bar thickness unless the applicable design explicitly permits that treatment.
A temporary shop primer and a fully specified industrial coating system have different costs and purposes. Surface preparation, coating chemistry, film thickness, curing, and inspection should be defined.
Traffic abrasion and contact with chemicals can affect coating life. Budget for inspection and repair in areas exposed to repeated wheel movement or scraping.
A compatible paint system over galvanizing can provide additional protection or appearance benefits. It adds preparation, application, curing, and future repair considerations.
304, 316, and other stainless grades may be appropriate where coating maintenance is difficult or the exposure warrants them. They generally increase initial material cost.
Stainless steel is not automatically stronger or universally corrosion-resistant. Select the grade, weld treatment, and finish for the actual environment while maintaining the same structural checks.
A heavy panel may be durable but difficult to remove for channel cleaning. Lifting points, panel modules, hinges where appropriate, and access procedures should be considered during procurement.
Ownership cost includes cleaning, inspection, coating repair, fastener replacement, lifting, downtime, and eventual panel replacement. No universal service life follows from the words “heavy duty” or “galvanized.”
A formal test-load value is not a vehicle mass rating. Actual wheel reactions, contact areas, traffic conditions, installation, and standard requirements still matter.
“Heavy duty” from two suppliers may describe different sections and assumptions. Compare numerical performance and supporting evidence.
Axle loads are not always equal, particularly for forklifts carrying loads. Obtain appropriate equipment data rather than assuming an even distribution.
A wheel creates a localized load. Its demand cannot be assessed reliably by spreading the vehicle’s weight over the full platform area.
Wheels can approach unsupported edges, openings, and joints. These positions may govern the design even when the panel center performs adequately.
Additional thickness may increase strength while leaving inadequate bearing, weak supports, loose restraints, or excessive span unresolved.
Higher yield strength does not provide a comparable increase in elastic stiffness. Geometry and support layout often remain the controlling factors.

Check the tested product, dimensions, support arrangement, frame, fixings, and applicable coverage of the evidence. A report for another size or construction does not automatically qualify the quoted panel.
A strong grating panel cannot compensate for an inadequate supporting assembly. Include frames, bearing details, connections, and anchorage in the scope.
Raw material rates exclude manufacture, fabrication, finishing, inspection, packing, and delivery. Use a consistent finished-product basis.
Heavy panels can require cranes, lifting equipment, traffic control, and planned access. Those costs belong in the project budget, even when the area price looks competitive.
An accurate heavy-duty quotation begins with the load schedule and support drawing. Once those are fixed, the supplier can propose a compliant section, identify its weight and fabrication requirements, and price the complete assembly. This provides a stronger purchasing basis than selecting a nominal duty label and searching for the lowest area rate.
How much does heavy-duty steel grating cost per m²?
CSSP’s published factory-budget guide gives approximately US$90–300 per m² as a broad reference for heavy-duty galvanized grating. Actual prices depend on bearing bar size, span, wheel or equipment loads, fabrication, finish, quantity, and verification requirements. Frames, formal classification testing, freight, installation, duties, and taxes may be additional. Obtain a quote against the complete design rather than treating this range as a price for a particular load class.
What load rating do I need for forklift grating?
Use the forklift’s maximum relevant wheel or axle loads, tire contact area, travel direction, operating conditions, and traffic frequency together with the grating span and support details. Rated lifting capacity alone is insufficient because it does not describe the truck’s total weight or wheel-load distribution. The panel, edges, frame, and restraints should all be verified for the specified operation.
Does D400 mean a grating can support a 40-tonne truck?
No. D400 is associated with a 400 kN test load under the conditions of the applicable product standard; it is not a universal allowable vehicle mass. Suitability depends on the qualified assembly, installation location, support construction, and actual traffic requirements. Confirm that the quoted product and its evidence meet the specified standard and project conditions.